Diagnostic Devices, Inc. www.prodigymeter.com
Prodigy Talking Meter Owner’s Manual
4
5
Diagnostic Devices, Inc. 1.800.243.2636
Prodigy Talking Meter Owner’s Manual
ReadthisbeforeusingyourProdigyAutoCode
®
Meter.
The following basic safety precautions should always be
taken.
•Closesupervisionisnecessarywhenthedeviceisused
by, on, or near children, handicapped persons or invalids.
•Usethedeviceonlyfortheintendedusedescribedin
this manual.
•Donotuseteststripsandcontrolsolutionsthatarenot
supplied by the manufacturer.
•Donotusethedeviceifitisnotworkingproperly,orifit
has suffered any damage.
•Beforeusinganyproducttotestyourbloodglucose,
read all instructions thoroughly and practice the test.
Do all quality control checks as directed and consult with
a diabetes healthcare professional.
Warning: Keep the test strip vial away from children;
the vial cap and the test strips can be a potential choking
hazard. Never chew or swallow a test strip. If this occurs,
please seek medical assistance immediately.
Important Safety Instructions
Severedehydrationandexcessivewaterlossmaycause
false low results. If you believe you are suffering from
severe dehydration; consult a healthcare professional
immediately.
Elevated blood triglycerides, reducing substances such
as uric acid and ascorbic acid at normal blood
concentration, or acetaminophen, dopa, methyldopa,
L-dopa, and tolbutamide at normal blood concentrations
should not significantly affect the results.
Testresultsbelow60mg/dL(3.3mmol/L)indicatelow
bloodglucose(hypoglycemia).Testresultsgreaterthan
240mg/dL(13.3mmol/L)indicatehighbloodglucose
(hyperglycemia).Ifyourresultsarebelow60mg/dLor
above 240 mg/dL, repeat the test, and if the test
resultsarestillbelow60mg/dL(3.3mmol/L)orabove
240mg/dL(13.3mmol/L),consultyourhealthcare
professional immediately.
Inaccurate results may occur in severely hypotensive
individuals or patients in shock. Inaccurate low
results may occur for individuals experiencing a
hyperglycemic-hyperosmolar state, with or without ketosis.
Critically ill patients should not be tested with blood glucose
meters.
Please refer to your test strip package insert for additional
important information.